Class: EEG¶
A scalp EEG acquisition. Its own attributes are the ones that materially distinguish recordings used in source-localized coordinate or image-based meta-analyses.
URI: neurostudy_ex:EEG
classDiagram
class EEG
click EEG href "../EEG/"
Acquisition <|-- EEG
click Acquisition href "../Acquisition/"
EEG : acquisition_duration_seconds
EEG --> "0..1" ExtractedNumber : acquisition_duration_seconds
click ExtractedNumber href "../ExtractedNumber/"
EEG : acquisition_type
EEG : brain_coverage
EEG --> "0..1" ExtractedBrainCoverage : brain_coverage
click ExtractedBrainCoverage href "../ExtractedBrainCoverage/"
EEG : device
EEG --> "0..1" Device : device
click Device href "../Device/"
EEG : eeg_channel_count
EEG --> "0..1" ExtractedInteger : eeg_channel_count
click ExtractedInteger href "../ExtractedInteger/"
EEG : eeg_placement_scheme
EEG --> "0..1" ExtractedString : eeg_placement_scheme
click ExtractedString href "../ExtractedString/"
EEG : eeg_reference
EEG --> "0..1" ExtractedString : eeg_reference
click ExtractedString href "../ExtractedString/"
EEG : local_id
EEG : modality
EEG --> "1" ExtractedModality : modality
click ExtractedModality href "../ExtractedModality/"
EEG : recording_type
EEG --> "0..1" ExtractedString : recording_type
click ExtractedString href "../ExtractedString/"
EEG : sampling_frequency_hz
EEG --> "0..1" ExtractedNumber : sampling_frequency_hz
click ExtractedNumber href "../ExtractedNumber/"
EEG : stable_id
Inheritance¶
- Acquisition
- EEG
Slots¶
| Name | Cardinality and Range | Description | Inheritance |
|---|---|---|---|
| sampling_frequency_hz | 0..1 ExtractedNumber |
Sampling frequency of the recording in hertz | direct |
| eeg_reference | 0..1 ExtractedString |
Reference scheme and location used for the raw recording | direct |
| eeg_placement_scheme | 0..1 ExtractedString |
Electrode placement system, such as the 10-20 or 10-10 system | direct |
| recording_type | 0..1 ExtractedString |
Recording organization, such as continuous, discontinuous, or epoched | direct |
| eeg_channel_count | 0..1 ExtractedInteger |
Number of simultaneously recorded EEG channels | direct |
| stable_id | 0..1 String |
UUID minted by the store the first time this entity appears, never by an extr... | Acquisition |
| local_id | 1 String |
Acquisition | |
| acquisition_type | 1 String |
The concrete subclass this record instantiates | Acquisition |
| modality | 1 ExtractedModality |
Imaging or recording modality | Acquisition |
| acquisition_duration_seconds | 0..1 ExtractedNumber |
Total usable acquisition or recording duration in seconds | Acquisition |
| device | 0..1 Device |
The scanner, amplifier, or recording system this acquisition was made on, by ... | Acquisition |
| brain_coverage | 0..1 ExtractedBrainCoverage |
How much of the brain the acquired volume contained | Acquisition |
Identifier and Mapping Information¶
Schema Source¶
- from schema: https://neurostuff.org/schemas/neuroimaging-study-extraction
Mappings¶
| Mapping Type | Mapped Value |
|---|---|
| self | neurostudy_ex:EEG |
| native | neurostudy_ex:EEG |
LinkML Source¶
Direct¶
name: EEG
description: A scalp EEG acquisition. Its own attributes are the ones that materially
distinguish recordings used in source-localized coordinate or image-based meta-analyses.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction
rank: 1000
is_a: Acquisition
attributes:
sampling_frequency_hz:
name: sampling_frequency_hz
description: Sampling frequency of the recording in hertz.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
domain_of:
- EEG
- FNIRS
range: ExtractedNumber
eeg_reference:
name: eeg_reference
description: Reference scheme and location used for the raw recording.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
domain_of:
- EEG
range: ExtractedString
eeg_placement_scheme:
name: eeg_placement_scheme
description: Electrode placement system, such as the 10-20 or 10-10 system.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
domain_of:
- EEG
range: ExtractedString
recording_type:
name: recording_type
description: Recording organization, such as continuous, discontinuous, or epoched.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
domain_of:
- EEG
range: ExtractedString
eeg_channel_count:
name: eeg_channel_count
description: Number of simultaneously recorded EEG channels.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
domain_of:
- EEG
range: ExtractedInteger
Induced¶
name: EEG
description: A scalp EEG acquisition. Its own attributes are the ones that materially
distinguish recordings used in source-localized coordinate or image-based meta-analyses.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction
rank: 1000
is_a: Acquisition
attributes:
sampling_frequency_hz:
name: sampling_frequency_hz
description: Sampling frequency of the recording in hertz.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- EEG
- FNIRS
range: ExtractedNumber
eeg_reference:
name: eeg_reference
description: Reference scheme and location used for the raw recording.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- EEG
range: ExtractedString
eeg_placement_scheme:
name: eeg_placement_scheme
description: Electrode placement system, such as the 10-20 or 10-10 system.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- EEG
range: ExtractedString
recording_type:
name: recording_type
description: Recording organization, such as continuous, discontinuous, or epoched.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- EEG
range: ExtractedString
eeg_channel_count:
name: eeg_channel_count
description: Number of simultaneously recorded EEG channels.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- EEG
range: ExtractedInteger
stable_id:
name: stable_id
description: UUID minted by the store the first time this entity appears, never
by an extractor, and kept across re-runs so a later extraction matches the same
entity.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
owner: EEG
domain_of:
- Arm
- Timepoint
- Group
- Task
- Condition
- Assessment
- Region
- Acquisition
- Device
- Analysis
- Measure
- Preprocessing
- ModelEstimation
- ModelTerm
- InferenceSettings
- Table
- CoordinateSet
- Study
range: string
pattern: ^[0-9a-f]{8}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{4}-[0-9a-f]{12}$
local_id:
name: local_id
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
identifier: true
owner: EEG
domain_of:
- Arm
- Timepoint
- Group
- Task
- Condition
- Assessment
- Region
- Acquisition
- Device
- Analysis
- Measure
- Preprocessing
- ModelEstimation
- ModelTerm
- InferenceSettings
- Table
- CoordinateSet
- Study
range: string
required: true
acquisition_type:
name: acquisition_type
description: The concrete subclass this record instantiates. Derived by the mapper
from the modality value's `instantiates`, never extracted.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
designates_type: true
owner: EEG
domain_of:
- Acquisition
range: string
required: true
modality:
name: modality
description: 'Imaging or recording modality. A value in the Modality vocabulary
also names the class holding this acquisition''s modality-specific parameters,
through that value''s `instantiates`.
Open vocabulary: write the source''s own wording in the field when nothing here
fits, because the value is required and a closed range would discard the whole
acquisition over one unrecognised word. Only a vocabulary value carries an `instantiates`,
so an acquisition outside it resolves to the base class until normalization
maps the wording back on -- which is why `acquisition_type` is derived rather
than extracted, and why an unmapped modality is worth reporting.'
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- Acquisition
range: ExtractedModality
required: true
acquisition_duration_seconds:
name: acquisition_duration_seconds
description: Total usable acquisition or recording duration in seconds. Useful
for filtering studies by the amount of data contributing to an analysis, especially
resting-state and continuous recordings.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- Acquisition
range: ExtractedNumber
device:
name: device
description: The scanner, amplifier, or recording system this acquisition was
made on, by identifier. Acquisitions made on one machine reference one record;
a second record asserts the study used a second machine.
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- Acquisition
range: Device
inlined: false
brain_coverage:
name: brain_coverage
description: 'How much of the brain the acquired volume contained. This is the
extent the SCANNER sampled, and it is a third axis distinct from the two the
schema already carries: `Analysis.spatial_scope` is what the analysis tested,
and `InferenceSettings.correction_scope` with `search_volume` is where multiple
comparisons were controlled. A voxelwise analysis over a volume that clipped
the cerebellum is `whole_brain` in scope and `partial` here, and an ROI analysis
of a whole-head acquisition is the reverse. Never infer this from either of
those.
It describes the volume behind the REPORTED results. A scan that clipped a structure
in participants who were then excluded is `whole_brain`, because the analysed
volume was not clipped; calling it `partial` would say the opposite of what
the results rest on.
A field of view or slice prescription in millimetres is not by itself a statement
of coverage. Where only the geometry is given, the value is an inference and
`value_source` records it as one. Which structure a partial volume missed is
not a field of its own -- the evidence span carries that detail.'
from_schema: https://neurostuff.org/schemas/neuroimaging-study-extraction/acquisition
rank: 1000
owner: EEG
domain_of:
- Acquisition
range: ExtractedBrainCoverage